What are the technical differences between BTL B1 & BTL C1?

Below are the main technical differences between BTL B1 & BTL C1.

       Main differences between B1 and C1                                   class

           BTL B1

             BTL C1

                       Ambient temperature

       −40…+75 °C

        −40…+85 °C

                            Interface type

             Analog

      Analog or IO-Link

                    number of max. outputs

                   1

                  2

                             Connector types

      S92 (M12 5-pin)

       S32 (M16 8-pin)

 

        S15 (M12 8-pin)

 

          S35 (M16 6-pin)

 

CA.   (PUR cable axial)

 

    S04 (M12 4-pin, IO-  Link)

                            Non-linearity max.

 ≤ 500 mm: ±200 µm

≤ 500 mm: ±50/60 μm

 

   > 500 mm: ±0,04 %   FS

> 500 mm: ±0,012 % FS

                               LED available

              No

                 yes

                                Configurable

              No

                 yes

                        Condition Monitoring

               No

    Yes (IO-Link devices)

For more details you can refer to

https://www.balluff.com/en-in/products/areas/A0001/groups/G0116