Inductive coupler connecting in series
- Two Balluff Inductive Coupler BIC systems can be connected in series.
- But this cuts the power in half from 500 mA to 250 mA.
- The maximum cable length between the individual components must be ≤ 20 m.
- Angular offset can no longer be guaranteed and the maximum air gap = 5mm.
- Therefore, the systems should be positioned accurately.